24v 1440W/2400VA Mecer UPS Inverter
SKU S235
Original price
R 3,650.00
-
Original price
R 3,650.00
Original price
R 3,650.00
R 3,650.00
-
R 3,650.00
Current price
R 3,650.00
EXTERNAL BATTERY REQUIRED - Requires 2 x 12V deep cycle batteries. Batteries not included.
Features:
- Simulated sine wave inverter
- Built-in AVR for voltage regulation
- Wide input voltage range: 90-280 VAC
- 24VDC
- Overload and short circuit protection
- LCD display for comprehensive information
Specifications:
- MODEL: Mecer IVR-2400LBK
- CAPACITY: 2400 VA / 1440 W
- POWER FACTOR: 0.6
- Input Voltage range 90-280VAC
Line Mode:
- Output Voltage
- Bypass mode: 0utput voltage same as input voltage
- AVR mode: Output voltage = Input voltage 1.2 at Input voltage - Output Frequency Same as input
Battery Mode:
- Output Voltage 230Vac +/-10%
- Transfer Time 20ms typical
- Waveform Modified Sine-wave
Overload Capability:
- Bypass Mode (in VA and Watts) Load >110%+/-15% , alarm 5 mins then fault
- Load >130% +/-15%, fault immediately.
- AVR Mode (in VA and Watts)at Input voltage > 170VAC Load >100%+/-15%, go to bypass mode
- AVR Mode (in VA and Watts)at Input voltage < 170VAC Load >60%+/-15%, go to bypass mode
- Battery Mode (in W) Load>110% +/-15%, overload alarm for 15s, and then will switch to fault mode for 10s. Then unit will re-start for 5 times Load>120% +/-15% , fault & cut off O/P immediately.
Short Circuit Protection:
- Line Mode Breaker
- Battery Mode Current limit +Firmware Protection
Battery:
- Battery Voltage 24 VDC
- Acceptable Battery Type Rechargeable lead-acid battery, Deep discharge battery
- Polarity Reserve Protection Yes
- Charger available I/P range 90~280V
- BATTERY’S NOT INCLUDED
Charger:
- Constant Current Charger Voltage 28.6VDC +/-2%
- Floating Charge Voltage 27.4VDC +/-2%
- Maximum Charge Current 10A or 20A
- DC Start Voltage >22VDC
Physical:
- Dimensions: D X W X H (mm) 350 x 90 x 300
- Net Weight (kgs) 5.5
Environment:
- Operating Humidity 0 to 90% Relative Humidity(Non-condensing)
- Operating Temperature 0 degrees C to 40 degrees C
- Storage Temperature -15 degrees C to 50 degrees C
Please note:
The optional solar charge controller for this unit is DISCONTINUED and no longer available
This unit will not turn on if not connected to at least two 12V batteries connected in series for 24V.
Fan will turn off once batteries are fully charged!
Not designed to run in a DB Board
This unit will not turn on if not connected to at least two 12V batteries connected in series for 24V.
Fan will turn off once batteries are fully charged!
Not designed to run in a DB Board